If you work with CBCT scans, you know the review can feel like searching a dense forest for a few specific trees. VELMENI, a dental artificial intelligence company, just gave clinicians a new set of eyes for that search.
The U.S. Food and Drug Administration has granted 510(k) clearance to VELMENI for DENTISTS (V4D) 3D, a software tool that brings AI-assisted review to dental cone-beam computed tomography imaging.
VELMENI for DENTISTS (V4D) 3D is now FDA 510(k) cleared to assist dental professionals in reviewing and analyzing CBCT scans, using AI-assisted segmentation, measurements, and reconstructed views to support, not replace, clinical judgment.
This matters for any practice running cone-beam imaging in-house or sending scans out for specialist review. The tool joins VELMENI’s existing 2D X-ray analysis software under one connected platform called VELMENI ONE.
If your practice or imaging center is weighing whether this kind of CBCT review tool fits your workflow, the details below walk through what got cleared, what it actually does, and where it might help. You can also visit velmeni.ai to learn more or schedule a demonstration.
Key Takeaways
- VELMENI for DENTISTS (V4D) 3D received FDA 510(k) clearance for AI-assisted review of dental CBCT scans, with segmentation, measurements, and reconstructed views as its core cleared functions.
- The software supports tasks like implant planning, endodontic assessment, and orthodontic evaluation by organizing CBCT data, but final diagnosis stays with the treating dentist.
- It connects to VELMENI ONE, the company’s broader platform that also includes 2D X-ray analysis, voice charting, and claims automation tools.
What Did the FDA Clear?
The FDA cleared VELMENI for DENTISTS (V4D) 3D under the 510(k) pathway, a process the U.S. Food and Drug Administration uses to confirm a new device is substantially equivalent to one already on the market.
This clearance, dated July 23, 2026 according to FDA device records compiled by Innolitics, covers software that reviews cone-beam computed tomography (CBCT) scans rather than the imaging hardware itself.
What Is VELMENI for DENTISTS 3D Designed to Do?
V4D 3D is built to assist dental professionals in reviewing CBCT datasets through AI-assisted segmentation, measurements, and reconstructed visualizations. It takes DICOM scan files, processes them through a machine-learning engine, and returns labeled anatomical structures along with panoramic and cross-sectional views, according to the FDA submission summary hosted by Innolitics. The software runs as a cloud-hosted, web-based platform, meaning there’s no new hardware to install alongside your existing CBCT unit.
What Does 510(k) Clearance Mean for This Software?
A 510(k) clearance means the FDA found the device substantially equivalent to a predicate device already legally marketed, in this case Pearl Second Opinion 3D, per the Innolitics device record. It is not the same as FDA “approval,” a distinction worth keeping straight when you’re explaining this to your team.
The cleared indications for use specifically cover detecting anatomical structures (maxilla, cranium, mandible, mandibular canal, temporomandibular joint, maxillary sinus, teeth, and airway) in CBCT scans of permanent teeth for patients 15 years and older, per the same FDA record.
The clearance also notes the software is a concurrent-read tool, meaning it provides extra information alongside the clinician’s own exam rather than issuing a standalone diagnosis.
How Does the Software Help Clinicians Review CBCT Scans?
The software’s core job is turning a dense CBCT volume into organized, labeled views a clinician can scan quickly. It identifies and segments anatomical structures, builds panoramic and cross-sectional images automatically, and lets you export 3D models when you need to share a case.
AI-Assisted Segmentation of Dental and Facial Anatomy
V4D 3D identifies, labels, and segments structures including the maxilla, mandible, mandibular canal, teeth, maxillary sinuses, temporomandibular joints, and airway, based on VELMENI’s clearance announcement. In testing submitted to the FDA, the segmentation models reported DICE scores (a measure of how closely the AI’s outline matches the true anatomy) ranging from 0.914 for the mandibular canal to 0.968 for the airway, with sensitivity as high as 100% for the mandible, maxilla, and maxillary sinus, according to the FDA performance data on Innolitics. Those figures come from bench testing on 127 de-identified CBCT images from four U.S. dental offices, not from a clinical outcomes study.
Practically, this means the software can draw outlines around the mandibular canal before an implant case, or flag the maxillary sinus floor before a sinus lift. You still confirm what it shows against the raw scan.
Panoramic Reconstruction, Cross-Sectional Views, and Measurements
The software automatically finds the dental arch and builds reconstructed panoramic and cross-sectional views from the CBCT volume, saving you from manually slicing through hundreds of images to find the right angle, according to VELMENI’s announcement on Dentistry Today.
It also provides clinically relevant measurements alongside high-resolution, multi-planar visualizations. For a dentist checking bone height before an implant, that means fewer manual clicks to get to the cross-section you actually need.
STL Export for Models and Collaboration
V4D 3D exports STL files, a standard 3D model format, for case presentations, patient education, and sending to specialists or dental labs. This is useful when you want a surgical guide fabricated or need to hand off a case to an oral surgeon with a shared 3D reference rather than a flat image.
Where Could 3D CBCT Review Fit in Dental Care?
Dental CBCT imaging already supports a range of clinical tasks, and V4D 3D’s segmentation and reconstruction tools are built to make reviewing those scans more efficient across several of them. The cleared indications tie directly to structures relevant for implant, endodontic, orthodontic, and airway-related review.
Implant, Endodontic, and Orthodontic Planning
Implant planning often depends on knowing exactly where the mandibular canal sits relative to a proposed implant site, and the software’s canal segmentation gives you a labeled reference point for that review.
For endodontic assessment, a cross-sectional view generated automatically can help you trace canal anatomy or check for periapical involvement without manually paging through slices. Orthodontic evaluation can draw on the 3D visualization of the maxilla and mandible together, useful when planning for skeletal relationships rather than teeth alone.
Airway and Other Anatomical Review
Airway segmentation was one of the better-performing outputs in the FDA’s clinical testing data, with a DICE score of 0.968 and 99.2% sensitivity, according to the Innolitics FDA record. That makes it relevant for practices reviewing airway volume as part of sleep-related or orthodontic workups.
Surgical review and general anatomical screening (checking sinus health, TMJ positioning) round out the other uses CBCT imaging already supports in daily practice.
How Does V4D 3D Connect to VELMENI ONE?
V4D 3D is one piece of VELMENI ONE, the company’s broader platform connecting imaging, documentation, and administrative tools for dental practices. The 3D CBCT tool sits alongside VELMENI’s existing 2D X-ray software and several non-imaging features built for day-to-day practice operations.
From 2D X-Ray Analysis to 3D Imaging
VELMENI’s earlier cleared product, VELMENI for DENTISTS (V4D), assists dentists in detecting caries, fillings, fixed prostheses, and implants on bitewing, periapical, and panoramic radiographs, per its own FDA 510(k) record on Innolitics.
That clearance dates to September 2025 and covers 2D radiographs specifically. V4D 3D extends that same AI-assisted review concept into three-dimensional CBCT data, but the two products have separate FDA clearances and separate indications for use. A dentist using both would see 2D findings on standard X-rays and 3D anatomical segmentation on CBCT scans, within the same connected platform.
Documentation, Reporting, and Administrative Tools
VELMENI ONE also includes voice-enabled periodontal charting, structured clinical documentation, CBCT reporting support, and dental insurance claims automation, according to coverage from Dentaltown.
These features sit outside the imaging clearance itself; they’re workflow tools meant to reduce administrative load around the clinical review, not part of what the FDA evaluated for V4D 3D. Worth noting for any practice evaluating the platform: the imaging analysis and the administrative automation are distinct capabilities, even though they live under one login.
Who Is the Software Intended to Support?
V4D 3D is intended for licensed dental professionals across general and specialty practice, plus larger organizations that manage imaging at scale. The FDA’s cleared indications specify use by “licensed dental professionals,” without limiting it to a single specialty.
General Dentists and Dental Specialists
The software is built for general dentists alongside oral and maxillofacial radiologists, oral surgeons, orthodontists, prosthodontists, and endodontists, according to VELMENI’s press release.
A general dentist might use it to get a quick read on a CBCT scan before referring a patient out, while a specialist might lean on the segmentation and measurement tools for more detailed surgical or orthodontic planning.
Dental Practices, DSOs, and Imaging Centers
Dental service organizations and standalone imaging centers are named as intended users too, which makes sense given the volume of CBCT scans those settings process. A multi-location DSO reviewing CBCT scans across several offices could use the cloud-based platform to standardize how scans get segmented and reported, rather than relying on each location’s manual review process.
What Should Practices Check Before Using It?
Before adopting V4D 3D, confirm the cleared indications match how you intend to use it, since the FDA clearance covers specific structures and a specific patient age range. The clearance applies to CBCT scans of permanent teeth in patients 15 years of age or older, with cleared detection limited to the maxilla, cranium, mandible, mandibular canal, TMJ, maxillary sinus, teeth, and airway, per the FDA’s indications for use on Innolitics.
Cleared Indications, Availability, and Workflow Fit
Check whether your CBCT unit’s DICOM export is compatible with the software’s cloud-upload process, since V4D 3D accepts scans in .zip format through a web interface. Ask how CBCT reporting fits into your existing documentation workflow, since structured reporting is part of the connected platform but works differently than a standalone radiology report.
Why Clinical Review Remains Essential
The clearance explicitly frames V4D 3D as a concurrent-read tool, additional information alongside your own exam, not a replacement for it. Final diagnosis and treatment planning stay with the treating dental professional, per the FDA’s own language in the clearance record. Any segmentation or measurement the software produces still needs your clinical eye on the original scan before it informs a treatment decision.
What the Clearance Means for Dental CBCT Workflows
This clearance gives dental teams an FDA-cleared option for AI-assisted CBCT review, built around segmentation, reconstruction, and measurement rather than autonomous diagnosis. The cleared indications are specific: structures like the mandibular canal, maxillary sinuses, TMJ, and airway, in patients 15 and older.
For practices already running CBCT in-house or working with imaging centers, it’s worth understanding where this tool fits into your existing review process and where your own clinical judgment still does the heavy lifting. If you want to see how it works with your own scans, VELMENI offers personalized demonstrations through velmeni.ai.
Frequently Asked Questions
Is VELMENI for DENTISTS 3D FDA approved or 510(k) cleared?
VELMENI for DENTISTS (V4D) 3D received FDA 510(k) clearance, not FDA approval. The clearance means the FDA found it substantially equivalent to an already-marketed predicate device, Pearl Second Opinion 3D, based on the FDA’s device record.
What can VELMENI’s AI identify in a dental CBCT scan?
The software identifies and segments the maxilla, cranium, mandible, mandibular canal, temporomandibular joints, maxillary sinuses, teeth, and airway structures. It also generates reconstructed panoramic and cross-sectional views from the CBCT data.
Does VELMENI for DENTISTS 3D diagnose conditions on its own?
No, the software is a concurrent-read tool designed to provide additional information during a clinician’s review. Final diagnosis and treatment planning remain the responsibility of the treating dental professional, per the FDA’s cleared indications for use.
Can the software generate panoramic views from CBCT scans?
Yes, V4D 3D automatically identifies the dental arch and builds reconstructed panoramic and cross-sectional views from CBCT datasets. This saves time compared to manually slicing through the full volume to find useful viewing angles.
How does V4D 3D differ from VELMENI’s 2D X-ray tools?
V4D 3D analyzes three-dimensional CBCT scans, while VELMENI’s earlier product, also called V4D, assists with detecting caries, fillings, prostheses, and implants on 2D bitewing, periapical, and panoramic radiographs. The two products hold separate FDA 510(k) clearances with distinct indications for use.

Leave a Reply